Rocky Mountain (56th Annual) and Cordilleran (100th Annual) Joint Meeting (May 3–5, 2004)
Paper No. 8-3
Presentation Time: 8:00 AM-5:00 PM

ACCURATE IN SITU THREE-DIMENSIONAL MEASUREMENT OF ECONOMIC TRACE PHASES IN GEOLOGICAL MATERIALS USING HIGH-RESOLUTION X-RAY COMPUTED TOMOGRAPHY

KETCHAM, Richard A. and MOTE, Alison S., Jackson School of Geosciences, The Univ of Texas at Austin, 1 University Station C1110, Austin, TX 78712, ketcham@mail.utexas.edu

High-resolution X-ray computed tomography (HRXCT) is a powerful method for nondestructively imaging the interiors of geological specimens. Each HRXCT image corresponds to a virtual slice through the object being scanned in which gray levels reflect relative X-ray attenuation, which is a function of density and atomic number. By acquiring a contiguous series of slice images, data describing an entire sample volume can be obtained. The high density and atomic number of many economic trace phases results in their having very high attenuation coefficients, making even very small grains distinguishable and potentially measurable. However, the finite resolution of tomography can complicate such determinations due to blurring and partial volume effects, which cause the attenuation signal of a particular grain to extend beyond its true boundaries, making high-attenuation trace phases appear larger than they actually are. We present here a methodology that has been developed to allow accurate measurement of the volume, shape and orientation of such trace phases by determining the total attenuation signal associated with each grain. The method was tested by embedding native gold grains with known dimensions and volumes and various shapes into a simulated rock matrix of quartz and epoxy, and scanning the sample at successively decreasing levels of spatial resolution. Overall, results obtained from analysis of the scan data are in excellent agreement with physical measurements of mass and cross-sectional area. Volume determinations were accurate even on grains with minimum dimensions of roughly 1/1000 of the imaging field diameter. As resolution decreases, accuracy is in part linked to grain shape, which can also be evaluated from the HRXCT imagery, allowing a compensating factor to be formulated.

Rocky Mountain (56th Annual) and Cordilleran (100th Annual) Joint Meeting (May 3–5, 2004)
Session No. 8
Economic Geology (Posters)
Boise Centre on the Grove: Flying Hawk and Falcon's Eyries
8:00 AM-5:00 PM, Monday, May 3, 2004

Geological Society of America Abstracts with Programs, Vol. 36, No. 4, p. 3

© Copyright 2004 The Geological Society of America (GSA), all rights reserved. Permission is hereby granted to the author(s) of this abstract to reproduce and distribute it freely, for noncommercial purposes. Permission is hereby granted to any individual scientist to download a single copy of this electronic file and reproduce up to 20 paper copies for noncommercial purposes advancing science and education, including classroom use, providing all reproductions include the complete content shown here, including the author information. All other forms of reproduction and/or transmittal are prohibited without written permission from GSA Copyright Permissions.