| 2007 GSA Denver Annual Meeting (28–31 October 2007) | |
| Paper No. 7-8 | |
| Presentation Time: 10:10 AM-10:25 AM | ||
AN EVALUATION OF PORTABLE X-RAY FLUORESCENCE FOR ARTIFACT SOURCING IN THE FIELD: CAN A HANDHELD DEVICE DIFFERENTIATE ANATOLIAN OBSIDIAN SOURCES? | ||
|
FRAHM, Ellery, Geology and Geophysics, Univ of Minnesota, 108 Pillsbury Hall, 310 Pillsbury Drive SE, Minneapolis, MN 55455, frah0010@tc.umn.edu Ideally chemical analyses used for sourcing studies could be conducted in the field, quickly, and nondestructively. Unfortunately, most techniques require immobile instruments. One technique with great potential for on-site analysis is portable energy-dispersive X-ray fluorescence (ED-XRF). Thermo Fisher Scientific's NITON analyzer is a handheld ED-XRF device about the size and shape of a cordless drill. It is typically used for environmental monitoring and scrap-metal testing. I evaluated an "off-the-shelf” model of NITON analyzer to see if it could differentiate Anatolian obsidian sources. The analyzer was used in a factory-set “bulk/soil” mode without further calibration, and the 21 elements measured were also preset. NIST standards were also analyzed to determine if its accuracy and precision for trace elements are sufficient for sourcing. Like all ED-XRF systems, this analyzer is susceptible to X-ray peak overlaps, causing misidentified elements and spurious element detection. A sample-size effect was also observed for some elements, as has been previously documented for XRF. Element concentrations were often under- or over-reported, typically by a factor of 2 to 3, although more at times. This strongly underscores the need for users to create custom calibrations for each material (e.g., obsidian based on rhyolitic glass standards) to improve accuracy. Testing established, though, that errors were mostly systematic. About two-thirds of the obsidian sources were clearly distinguished. Other source fingerprints overlapped, and some overlaps had important implications for archaeological interpretation. Also, if the data are only internally consistent, one cannot use them directly with existing source databases. Any archaeological applications of the analyzer must play to its strengths, notably portability. This instrument might be most useful in archaeology as a “first sort” tool: one can analyze hundreds of artifacts on-site, explore the data for chemical clusters, select representative samples from each cluster for export and later lab-based analyses, and supply the initial data in artifact export requests. Portable ED-XRF is one of only a handful of techniques that shows potential for initial on-site chemical sorting of artifacts, and I am planning further tests using my own custom calibrations. | ||
|
2007 GSA Denver Annual Meeting (28–31 October 2007)
General Information for this Meeting | ||
| Presentation Handout (.pdf format, 2190.0 kb) | ||
| Session No. 7 Sourcing Techniques in Archaeology Colorado Convention Center: 504 8:00 AM-12:00 PM, Sunday, 28 October 2007 Geological Society of America Abstracts with Programs, Vol. 39, No. 6, p. 29 | ||
© Copyright 2007 The Geological Society of America (GSA), all rights reserved. Permission is hereby granted to the author(s) of this abstract to reproduce and distribute it freely, for noncommercial purposes. Permission is hereby granted to any individual scientist to download a single copy of this electronic file and reproduce up to 20 paper copies for noncommercial purposes advancing science and education, including classroom use, providing all reproductions include the complete content shown here, including the author information. All other forms of reproduction and/or transmittal are prohibited without written permission from GSA Copyright Permissions. | ||