GSA Connects 2023 Meeting in Pittsburgh, Pennsylvania

Paper No. 256-9
Presentation Time: 4:05 PM

LONG-DURATION MONITORING AND MASS BALANCE OF PFAS AT A WASTEWATER TREATMENT PLANT FOLLOWING THE RELEASE OF AQUEOUS FILM-FORMING FOAM CONCENTRATE


VITALE, Donovan, Geological and Environmental Sciences, Western Michigan University, 1903 W Michigan Ave, Kalamazoo, MI 49008

Approximately 760 liters (200 gallons) of first-generation, PFOS-dominant, Aqueous Film-Forming Foam (AFFF) concentrate entered the sanitary sewer after an accidental release at the Kalamazoo/Battle Creek International Airport and migrated 11.4 km to the Kalamazoo Water Reclamation Plant. Near-daily sampling of influent, effluent, and biosolids generated a high-frequency, long-duration dataset used to understand the transport and fate of accidental PFAS releases to wastewater treatment plants, identify AFFF concentrate composition, and perform a plant-wide PFOS mass balance. Monitored influent concentrations exhibited sharp PFOS declines after 7 days post-spill, yet effluent discharges remained elevated due to return activated sludge (RAS) recirculation, resulting in the exceedance of Michigan's Surface Water Quality Value for 46 days. Mass balance estimates indicate 1.292 kg PFOS entering the plant and 1.368 kg leaving. Effluent discharge and sorption to biosolids account for 55% and 45% of estimated PFOS outputs, respectively. Identification of AFFF formulation and reasonable agreement between computed influent mass and reported spill volume demonstrates effective isolation of the AFFF spill signal and increases confidence in the mass balance estimates. These findings and related considerations provide critical insight for performing PFAS mass balances and developing operational procedures for accidental spills that minimize PFAS releases to the environment.